Golden Technology
Comercializadora de Bienes y Servicios; Tecnología Dorada del Sur de Tamaulipas S.A. de C.V.
Contactanos: (833) 213 36 50
Pag 49 a la pag. 51
AT820 Series
(AT824/ AT825/ AT826)
2.8 inch True-color TFT display
Parameters: L, C, R, Z
Monitor: D, Q, θr, θd, X, ESR
Keypad and Touch screen double control
Frequency range:100Hz ~ 1kHz/10kHz/100 kHz
USB interface, Li-on battery supply power
AT2816 Series
(AT2816A/ AT2816B)
Frequency range from 50Hz to 200kHz Parameters:Cs-Rs, Cs-D, Cp-Rp, Cp-D,Lp-Rp, Lp-Q,Ls-Rs, Ls-Q, G-B, R-X, Z-θrad, Z-θdeg Monitor:Z,D,Q,θr,θd,R,X,G, B, Y, Vac, Iac, Δ, Δ% Accuracy 0.05% ±5 dgt / 0.1%
Interface: RS232C and Handler
Optional Interface: USB
VICTOR 6243
Capacitance:2nF/20nF/200nF/2uF/20uF/200uF/1000uF Inductance:2mH/20mH/200mH/2H/20H Buzzer alarm, data hold, Diode function Transistor function
DM4070
Capacitance:200pF/2nF/20nF/200nF/2uF/20uF /200uF/2000uF Inductance:200uH/2mH/20mH/200mH/2H/20H Resistance:20Ω/200Ω/2kΩ/20kΩ/200kΩ/20MΩ Strong antimagnetic and anti-jamming performance
AT2818
Frequency range from 10Hz to 300kHz (continuous frequency,frequency resolution 0.001Hz)
Parameters:Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q, Ls-Rs,Ls-Q,Rs-Q,R-X,Z-θrad,Z-θdeg Monitor:Z,D,Q,θr,θd,R, X, G, B, Y, Vac, Iac, Δ, Δ% Accuracy: 0.05% ±5 dgt
Interface: RS232C and Handler Optional Interface: USB-Disk and USB-232
TH2827 Series
(TH2827A/TH2827B/TH2827C)
4.3-inch TFT LCD display
Frequency range: 20Hz ~ 300kHz/500kHz/1MHz
10mHz resolution,4-digit frequency input 0.01%
accuracy Test parameters: |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Integrated transformer test function
Balance test function
Maximum test speed: 13ms/time
Automatic level control (ALC) function for V and I
Test signal level monitor function for V and I
Included interior DC bias source External DC bias source of large current
10-point list sweep function
Selectable internal resistance of 30Ω,50Ω and 100Ω
Internal file storage and external USB-disk
RS232C, USB, LAN, HANDLER, GPIB, DCI interface
AT801A
Frequency range from 10Hz to 20kHz Parameters:Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, R-X, Z-θrad, Z-θdeg Monitor: Z,D,Q,θr,θd,R,X,G,B,Y,Vac, Iac, Δ, Δ% Accuracy: 0.05% ±5 dgt Interface: RS232C and Handler Optional Interface: USB
AT2817A
Frequency range from 50Hz to 100kHz Parameters:Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, R-X, Z-θrad, Z-θdeg Monitor: Z,D,Q,θr,θd,R,X,G,B,Y, Vac, Iac, Δ, Δ% Accuracy 0.05% ±5 dgt Interface: RS232C and Handler Optional Interface: USB
TH2829 Series
(TH2829A/TH2829B/TH2829C)
7-inch TFT LCD display, 0.05% basic accuracy Frequency range:20Hz ~ 300kHz/500kHz/1MHz 1MHz frequency and 1mHz resolution Strongest signal source selection:
10V/100mA programmable AC test level 10V/100mA programmable DC bias supply 10V/50mA standalone DC voltage source 1A interior DC bias current source (optional)
120A external bias source (optional)
Testparameters:|Z|,|Y|,C,L,X,B,R,G,D,Q,θ,DCR,Vdc-Idc
Simultaneous display of 4 kinds of test parameters 10 pages/150-point list sweep function Continuous curve scanning/graphical analysis function USB storage GIF image and CSV data files directly
Standardinterface:HANDLER,USB,LAN,RS232C,DCI Standard interface:GPIB
VC6013
Range:200pF/2nF/20nF/200nF/2uF/20uF/200uF /2000uF/20mF
Strong antimagnetic and anti-jamming performance
Full protect function, with capacitor self discharge
This digital capacitance multimeter can accurately measure low capacitance.
0.5% high accuracy
TH2622
Measurement accuracy up to 0.5%
Measurement range:0.1pF~199.99mF
4 ½ digits display,maximum readings up to 11,000 Measurement range from 0.1pF to 199.99mF Auto/Manual range selection and relative function
25 sets of HI/LO limit comparison setup
4 tolerance comparator modes: 1%,5%,10%,20%
Standard Mini-USB interface
Support SCPI commands
VC6013
Range:20 mΩ/200 mΩ/2Ω/20Ω/200Ω/2kΩ
3 ½ digits display,Max.display: 1999
3 times/s Sampling rate
lightning protection network,equalizing ring of glass
curtain walls, and communication antenna;
High measurement range of 0.01mΩ to 2kΩ at 6 ranges HOLD key for data hold
Backlit LCD for easy reading under dark light
Connection for external power supply
Strong anti-magnetic and anti-jamming functions
Full function protection
AT518 Series
(AT518/ AT518L)
3.5 inches, Truecolor 16M, TFT-LCD Display
Test parameters: DC resistance
Measurement Range: 10μΩ~20MΩ /10μΩ~200KΩ Accuracy: 0.05% / 0.10%
Automatic power off Function
ABS/ PER/SEQ comparison criteria
Comparator Function: GD/NG Show
Auto Zero-Adjust for each range Four-terminal resistance measurement.
Mini-USB interface;SCPI command sets
Keypad lock function; Automatic shutdown set Background-lightness adjustment function Suitable for low resistance character of Electromechanical Components
AT528 Series
(AT528/ AT528L)
Test parameters: AC resistance, DC voltage Resistance: 0.01 mΩ~2kΩ
Voltage: 1 mV~50V (AT528)
Resistance: 0.1 mΩ~200Ω
Voltage: 0.001V~50V(AT528L)
Accuracy: Resistance: 0.5%±5dgt Voltage: 0.1%±5dgt (AT528)
Resistance: 0.5%±5dgt Voltage: 0.5%±5dgt(AT528L) Gorgeous dual-colure cast shell,TFT-LCD Display Double display: ΔABS/Δ%/Sorting Result Comparator Function:GD/NG VFD Show or HANDLER out Auto Zero-Adjust for each range Four-terminal resistance measurement
Mini-USB interface
SCPI compatible command sets
Keypad lock and Data Hold function
VC6013
Earth resistance range: 0-1999Ω.
Earth voltage range: 0-199.9V.
3 ½ digit LCD display with 32mm high figure
Overload protection:
At earth voltage range,Max voltage can be 450V AC
At earth resistance range,Max voltage can be 280V AC Test lock and hold function White backlight
Victor 4105 Series
(4105A/ 4105B)
Earth resistance range: 20Ω~2000Ω/ 10Ω~1000Ω Earth voltage range: 200V / 750V
Full-featured,high accuracy,convenient and reliable operation, dustproof moisture-proof structure
Can be used to measure a variety of power systems, electrical equipment, lightning protection equipment grounding system grounding resistance value and AC voltage
AT510 Series Micro ohm Meter
(AT510/ AT510L)
Parameters: DC resistance
Measurement Range: 1μΩ~3MΩ/1μΩ~30kΩ
Basic accuracy:0.05% / 0.1%
High brightness, ultra clear four-color VFD Display Double display: ΔABS/Δ%/Sorting Result Zero-setting Function: short circuit zero-setting function Self-Calibration: Thermoelectromotive force compensation Heavy current test mode(Open voltage <20mV)
Four-terminal resistance measurement
Build-in RS-232C, Handler(EXT-I/O) interface
Beeper and brightness can be adjusted Internal,Manual,External or Remote Trig
GPIB/USB Interface(Optional)
SCPI compatible command sets Keypad lock and Data Hold functions
AT520 Series
(AT520/ AT520L)
Parameters:AC resistance,DC voltage, X,Z,θ,L(AT520) Parameters:AC resistance, DC voltage, θ (AT520L) Resistance range: 10μΩ~3 kΩ/ 10μΩ~32Ω;
Voltage range: 100μV~60VDC / 1mV~60VDC
Inductance: 10nH - 1H (Only for AT520)
Four Colors VFD Display
Vector Measurement, 3 Parameters Display
Comparator (sorting) Function): Build-in 30 sets comparators,
HI/IN/LOW/GD/NG Display and Output
Four-terminal resistance measurement
Beeper and brightness can be adjusted Internal,Manual,External and Remote Trig Build-in RS232C and Handler, GPIB(Optional)
Compatible with SCPI command sets
Keypad lock and Data Hold functions
VC60B+
Insulation Resistance Meter
Insulation resistance: 0~2GΩ
Resistance: 0~2kΩ
Large LCD display, easy to read
Strong anti-magnetic and anti-jamming function
Full function protection,anti high voltage circuit design Unit symbol display, easy to use
High voltage and short circuit input alarm
VICTOR 60E+
Insulation Resistance Meter
Measuring Range: 0.05GΩ~200GΩ AC-DC voltage:DC:2500V/5000V; AC:750V
Max display:1999
Low Battery Indication
Alarm Function
Overload Indication
Unit Symbol Display
Auto power off
VICTOR 60D+
Insulation Resistance Meter
Max display:1999
Measuring Range: 6MΩ~20GΩ AC-DC
voltage: DC:1000V/2500V; AC:750V
Low Battery Indication,Overload Indication,Alarm Function,Overload Indication,Unit Symbol Display,
Auto power off ons
VICTOR 3125
Insulation Resistance Meter
Measuring Range: 0~1.20TΩ
Measurement speed approx.0.5 times/s
AC-DC voltage:DC:0~±1000V;AC:30~600V(50/60Hz)
Max display:9999,36 bar graph display
Measurement speed approx.0.5 times/s
Build-in real-time clock
Isolate USB interface with computer communications
AT682/AT683
Insulation Resistance Mete
Parameters:Leakage current and insulation resistance Measurement Range:
AT682 10kΩ~1TΩ (104~1012W) 10V: 10kΩ~10GΩ 100V: 100kΩ~100GΩ 1000V: 1MΩ~1000GΩ
AT683 100kΩ~10TΩ 10V: 100kΩ~100GΩ; 100V: 1MΩ~1TΩ; 1000V: 10MΩ~10TΩ
3-lines VFD Display
Comparator: 30 files, GD/NG Beeper
Interface: RS232C and Handler
Optional Interface: USB
Programming Language: SCPI