top of page

Calibradores digitales e instrumentos de prueba.

 

 

ETX-1825/ ETX-2025

Multifunction Calibrator

 

A split-screen display. The upper display allows you to measure volts, current (with loop power), resistance and continuity test. The lower display allows you to measure and source volts, current, RTD,TC, frequency,and ohms. ETX-1825 Accuracy:0.05% of reading + 2 Counts

ETX-2025 Accuracy:0.025% of reading + 2 Counts Thermocouples type:J,K,T,E,R,S,B,N RTD sensors of Pt100,Pt1000,Cu50 and Cu100

ETX-1815/ ETX-2015 

Current and Voltage Calibrator

 

Source of voltage, current and frequency

Measure of voltage, current, loop current and frequency ETX-1815 Accuracy:0.05% of reading + 2 Counts

ETX-2015Accuracy:0.02% of reading + 2 Counts

ETX-1814/ ETX-2014 

Thermocouple Calibrator

 

Output of DC mV and simulation of thermocouple output Voltage, DC mV and thermocouple measurement

Manual stepping, automatic stepping, 0~100% phase step and slope output

Thermocouples type:J,K,T,E,R,S,B,N

ETX-1814 Accuracy:0.05% of reading + 2 Counts

ETX-2014Accuracy:0.02% of reading + 2 Counts

ETX-1812/ ETX-2012

RTD Calibrator

 

Measure voltage, resistance, and RTD

Outputs resistance, simulation of RTD

Manual stepping, automatic stepping, 0~100% phase step and ramp output

RTD sensors of Pt100,Pt1000,Cu50 and Cu100 ETX-1812 Accuracy:0.05% of reading + 2 Counts ETX-2012 Accuracy:0.02% of reading + 2 Counts

ETX-1810/ ETX-2010 

Temperature Calibrator

 

Measure DC V, DC mV, resistance ,TC and RTD

Outputs resistance, simulation of TC and RTD

Manual stepping, automatic stepping, 0~100%

phase step and slope output

Thermocouples type:J,K,T,E,R,S,B,N

RTD sensors of Pt100,Pt1000,Cu50 and Cu100

ETX-1810 Accuracy:0.05% of reading + 2 Counts

ETX-2010 Accuracy:0.02% of reading + 2 Counts

VICTOR 25

Multi-function Process Calibrator

 

Measures DC Voltage, Current to 50mA, Ohms to 5.5000KΩ, Frequency to 10KHz,

Thermocouple types: R, S, K, E, J, T, N and B;

RTD sensors of PT100, PT1000 and Cu50

Switch, continuity test and pressure through pressure transducer modules

Accuracy:±0.02%

VICTOR 11+

Process Calibrator

 

High Accuracy of 0.02% for source

6 digits display for source

The range of the internal temperature compensation sensor is from 0°C to 40°C

Thermocouple types: R, S, B,E,K, J, T ,N,L and U

VICTOR 02

Thermo Resistance Calibrator

 

Measures Voltage:100mV/1000mV

Thermocouple types: R, S, B,E,K, J, T and N;

VICTOR 03

Thermo Resistance Calibrator

 

Resistance to 400Ω

Thermo-resistance of PT100 and Cu50,

VICTOR 01

Temperature Calibrator

 

Measures Voltage, Resistance to 400Ω

Thermocouple types: R, S, B,E,K, J, T and N

RTD sensors of PT100 and Cu50

VICTOR 14+

Temperature Calibrator

 

Measures Voltage, Resistance to 400Ω

Thermocouple types: R, S, B,E,K, J, T and N

RTD sensors of PT100 and Cu50

VICTOR 04

Temperature Calibrator

 

Voltage to 10V; Current to 20mA

Analogue transducer to -20mA 24V Loop power

VICTOR 15+

V/mA Calibrator

 

High Accuracy of 0.02% for measure and source 5 digits display for measure and 6 digits for source DCV to 10V; DCA to 20mA FREQ:100Hz/1kHz/10kHz PULSE:100Hz/1kHz/10kHz; 24V LOOP 

AT4200 Series

(AT4202/ AT4204/ AT4208)

2.8 inch TFT-LCD display,Touch screen

 

Standard model for 2/4/8 channels Thermocouple:J/K/T/E/S/N/B

Measurement Range:-200.0 °C~1300.0 °C

(variation depend on graduation)

Li 1400mA rechargeable battery

AT4808

 

Standard model for 8 channels

(Max extend to 128 channels)

Thermocouple: J/K/T/E/S/N/B

Measurement Range:-200.0 °C~1300.0 °C

(According to different thermocouple type)

Built in li-ion battery

AT4500 Series

(AT4508/ AT4516/ AT4524/ AT4532)

 

3.5 inch TFT-LCD display

Standard model for 8/16/24/32 channels

(Max extend to 128 channels)

Thermocouple: J/K/T/E/S/N/B

Measurement Range:-200.0 °C~1300.0 °C

(According to different thermocouple type)

AT4600 Series 

(AT4610/ AT4620/ AT4640)

 

7 inch TFT-LCD display,Touch screen

Standard model for 10/20/40 channels

Thermocouple: J/K/T/E/S/N/B

Measurement Range:-200.0 °C~1300.0 °C

(According to different thermocouple type)

Support communication transmission

ST530 Series 

(ST530A/ ST530B/ ST530C)

 

Temperature range: -32ºC~530ºC (-25.6º F~986º F) Distance Spot Ratio:12: 1

Spectral response:8~14um

Resolustion:0.1º C of 0.1º F

Accuracy :± 2 ºC or 2 %

Non contact Infarared thermometer

Over-range indication

Automatic data holding

ST380 Series 

(ST380+/ ST380B/ ST380C)

 

Temperature range: -32º C~380º C (-25.6º F~716º F) Distance Spot Ratio:12: 1 Spectral response:8~14um Resolustion:0.1º C of 0.1º F Accuracy :± 2 ºC or 2 % Non contact Infarared thermometer Over-range indication;Automatic data holding

DM6801A+ 

3 ½ digits,Max.reading: 1999

 

K type thermometer with large LCD display

Temperature range: -50~1300 ºC(-50~1999 ºF)

0.1ºC / 0.2 ºF resolution

Low battery indication Data hold,Unit symbol display

Function protect

Anti-shock protect

Manual range

DM6802A+

3 ½ digits,Max.reading: 1999

 

K type thermometer with large LCD display

Temperature range: -50~1300 ºC(-50~1999 ºF)

0.4% high resolution

Low battery indication

Data hold,Unit symbol display

Function protect

Anti-shock protect

Manual range

DM6803A+

4 ½ digits,Max.reading: 19999

 

Support K, E, J, T, N, B, R, S thermocouples Temperature range: -40°C~1760°C (R type) -200°C~1370°C (K type) 0.1ºC high resolution

Low battery indication

Data hold,Unit symbol display

Function protect,Anti-shock protect

Manual range

DM6804A+

 

Support K, E, J, T, N, B, R, S thermocouples Dual channel display T1,T2,T1-T2

Temperature range:

-40°C~1760°C (R type) -200°C~1370°C (K type)

0.1ºC high resolution

Low battery indication

Data hold,Unit symbol display

Function protect,Anti-shock protect

Manual range 

SSN-50/SSN-51/SSN-52/SSN-53

Carbon Monoxide Data Logger with USB Interface

 

Carbon Monoxide Range:

0 ~ 1000PPM(SSN-50)

0 ~ 1000PPM(SSN-51)

0 ~ 3000PPM(SSN-52)

0 ~ 3000PPM(SSN-53)

Carbon Monoxide Accuracy:

±6% (SSN-50/SSN-51)

±4% (SSN-52/SSN-53)

Carbon Monoxide Resolution:0.5PPM

USB interface directly communicate with PC

Logger With USB Interface and LCD Display(for SSN-51/53)

Support for multiple file formats: txt, xsl, csv, bmp, jpg Start logging method: Immediately, Button, Delayed

AM821/AM831/AM841 

 

AM821: Flow velocity measuring instrument.

AM831: Flow velocity measuring instrument with temperature measurement and chill temperature. AM841: Measure flow speed, volume flow, temperature and chill temperature

Parameters: Knots, mph, km/h, m/s, ft/min, Bft Air

speed: 0.4~ 30m/s ;

Temperature: -10~ 50ºC/14~122ºF

Volume flow: CFM: 0 ~ 999, 990 ft3/min CMM: 0 ~ 999, 990 m3/min

Resolution: 0.1m/s, 0.1º C or 0.1º F

Built-in Ø 65 mm vane 

ST8020

 

Special function: Auto power off; Data hold; MAX, MIN and AVG; Backlit Measure: M/s,km/h, FPM,mph, kts,Beaufort scale, ° C,° F, wind chill. Resolution: 0.1 m/s, 1 FPM, 0.1º C, 0.1º F Range: 0.4~20 m/s, 80~4000 FPM, -10-50C Sample Rate: 0.5sec Auto power off: About 10 minutes idle Battery life: Continuous work 360 Hours(without backlit) Operating temperature: -10~50º C, 14~122º F

ST8021

 

Special function: Auto power off; Data hold; MAX, MIN and AVG; Backlit; Overload display; Low battery indicator Measure: M/s, km/h, FPM, mph, kts, Beaufort, %RH, td(dew point temperature), ° C, ° F

Resolution: 0.1 m/s, 1 FPM, 0.1%RH, 0.1º C, 0.1° F

Range: 0.4~20 m/s, 80~4000 FPM, 0~100%RH, -10~50º C, 14~122º F

Accuracy: ± (2% of reading + 0.3m/s) ± 3%RH (5~95%RH) ; ± 1º C, ± 1.8º F Sample Rate: 0.5sec

Auto power off: About 10 minutes idle 

ST8010 

 

Measure Parameters: º C,º F,%RH(relative humidity), td(dew point temperature), wb (wet bulb included) Range: -10 ~ +50º C, +14 ~ +122º F, 0 ~98%RH

Resolution: 0.1º C, 0.1º F; 0.1%RH Accuracy: ± 1.0º C, ± 1.8º F, ± 3%RH (5~95%RH)

Sample Rate: 0.5 time sec Auto power off: About 10 minutes idle Special function: Auto power off with disable feature; Data hold; MAX MIN; Backlit. Operating temperature: -10~50º C, 14~122º F

TH821 Humidity / Temperature Meter 

 

Sensor: Long-term stable humidity sensor,Capacitive. NTC Temperature sensor Measuring Range: 5~95%RH; 0~50º C / +32 to 122º F Accuracie± 1digit: ± 3%RH (at 5~95%RH) ± 0.5º C Resolution: 0.1%RH; 0.1º C/º F;Repeatability: ± 2% Response time (33 to 76%RH, still air): 5Sec. Long term stability: 0.5%RH per year Ambient conditions: 0 ~ 50 º C/32 ~ 122º F Storage/transport condition: -10~60º C,14 ~140º F Hold function and max. /min. Values Air moisture and air temperature

TH816 Thermo / Hygrometer 

 

Probe type: Humidity sensor, Capacitive NTC Temperature sensor Measuring range:10%~95%RH; 0~50º C / +32 to 122º F Accuracy± 1digit: ± 3%RH ;± 1ºC (+25º C) / ±1.8º F (+77ºF) Resolution: 1%RH, 0.1º C/0.1º F Comfort level:

HOT (over 34º C, over 80%RH)

WARM (at 30~34º C, 75%~80%RH)

CFT (at 20~28º C, 65%~75%RH)

COOL (at 12~20º C, 55%~65%RH)

COLD (below 12º C, 40%~50%RH).

SL821 

 

Sound pressure level (Lp), equivalent continous sound pressure level (Laeq), sound exposure level (LAE), and peak sound level (LCpeak) Microphone: 1/2 polarization capacity microphone A-weighting: 30dB~130dB; C- weighting:35dB~130dB Measurement frequency range: 31.5Hz to 8kHz Time weighting characteristics: FAST; SLOW

Calibration: 94dB;Data recording; 10

Bar graph: Scale range 50dB, 1dBresolution

Warming indicators: OVER (overload), UNDER(underload)

SL821 

 

Sound pressure level (Lp), equivalent continous sound pressure level (Laeq), sound exposure level (LAE), and peak sound level (LCpeak) Microphone: 1/2 polarization capacity microphone A-weighting: 30dB~130dB; C- weighting:35dB~130dB Measurement frequency range: 31.5Hz to 8kHz Time weighting characteristics: FAST; SLOW

Calibration: 94dB;Data recording; 10

Bar graph: Scale range 50dB, 1dBresolution

Warming indicators: OVER (overload), UNDER(underload)

TI395 - Features and Benefits

 

TeThermal imaging camera for temperature measurement

UFPA detector, 384x288 pixels

Excellent thermal images : NETD<50mk at 30°C

Auto|Manual focus for one-hand operation

270°rotatable LCD, Built-in 3.0 mega pixel visual camera

Movable and resizable P-I-P and thermal fusion

Optional wide-angel lens & telephoto lens

Built-in microphone and voice annotation

Real time thermal video transfer to PC via USB,

remote transfer via MSN and Skype

Li-ion battery more than 3 hours'operation

LD80 Measure 0.1-80m (0.32 to 262.5ft)

 

Measurement Distance: 0.1m~80m;0.32 in~262.5 ft Accuracy: ± 1.5 mm;± 0.06 in Laser type: 635nm, <1mW, Class II laser Auto. switch-off: after 0.5 min Auto off: 3 minutes ;Continuous measurement Min/Max distance tracking ;20 data records Battery Life: 4000times Power supply: 3*1.5V, AAA 

SW-40 40m Wide measuring range of up to 40m

 

Automatic calculation of area and volume Continuous measurement and Min/Max distance tracking Easy addition/subtraction of measurement Selectable meter(m), inch(in) and feet (ft) Bubble level design for precision measurement 99 data records Pythagorean indirect measurement function

SW-60 60m

 

Wide measuring range of up to 60m Automatic calculation of area and volume Continuous measurement and Min/Max distance tracking Easy addition/subtraction of measurement Selectable meter(m), inch(in) and feet (ft) Bubble level design for precision measurement 99 data records Pythagorean indirect measurement function

 

 

SW-60 60m

 

Wide measuring range of up to 60m Automatic calculation of area and volume Continuous measurement and Min/Max distance tracking Easy addition/subtraction of measurement Selectable meter(m), inch(in) and feet (ft) Bubble level design for precision measurement 99 data records Pythagorean indirect measurement function

 

 

SW-900A/SW-1200A/SW-1500A

 

Measurement Distance: 5-900m/1200m/1500m Accuracy: ± 1.0 m Magnification:6X Diopter Adjustable Range:±5° Objective Caliber: 25.0mm Eyepiece Caliber: 16.0mm Exit Pupil Caliber: 3.8mm Viewing Angle:7° Laser Wave Length: 905nm

 

CP-401 40m

 

Max Measuring Distance: 40m

Accuracy: ±1.5mm(± 0.06 in); Units: mm/in/ft

Laser Type: Class 2 635nm,<lm W

Consecutive/Area/Volume/Pythagorean Proposition Indirect

Add/Subtract/Max/Min/Backlight/Buzzer Indicator

Splash Proof/Dust Proof ;Auto Power-off

Battery Life: 4000times ; 20 data records

Power supply: 2*1.5V, AAA 

CP-501 50m

 

Max Measuring Distance: 50m

Accuracy: ±1.5mm(± 0.06 in); Units: mm/in/ft

Laser Type: Class 2 635nm,<lm W

Consecutive/Area/Volume/Pythagorean Proposition Indirect

Add/Subtract/Max/Min/Backlight/Buzzer Indicator

Splash Proof/Dust Proof ;Auto Power-off

Battery Life: 4000times ; 20 data records

Power supply: 2*1.5V, AAA 

 

CP-601 60m

 

Max Measuring Distance: 60m

Accuracy: ±1.5mm(± 0.06 in); Units: mm/in/ft

Laser Type: Class 2 635nm,<lm W

Consecutive/Area/Volume/Pythagorean Proposition Indirect

Add/Subtract/Max/Min/Backlight/Buzzer Indicator

Splash Proof/Dust Proof ;Auto Power-off

Battery Life: 4000times ; 20 data records

Power supply: 2*1.5V, AAA

 

CP-701 70m

 

Max Measuring Distance: 70m

Accuracy: ±1.5mm(± 0.06 in); Units: mm/in/ft

Laser Type: Class 2 635nm,<lm W

Consecutive/Area/Volume/Pythagorean Proposition Indirect

Add/Subtract/Max/Min/Backlight/Buzzer Indicator

Splash Proof/Dust Proof ;Auto Power-off

Battery Life: 4000times ; 20 data records

Power supply: 2*1.5V, AAA 

 

ST8030 100 to 30000 rpm; 1.7-500rps

 

LCD Display: 5 digits, with backlight Test Range: 100 to 30000 rpm; 1.7-500rps Resolution: 0.1 rpm (100 to 9999.9 rpm) 0.1rps (1.7 to 100rps) 1 rpm (1000-30000rpm) 1rps (100-500rps) Accuracy: +/-(0.02%n +2d) Sampling Time: 1 Sec (over 100 rpm) Number of impeller setting: 1-9 Test Range Selection: Automatic Detecting Distance: 100-400mm; 3.9-15.7" 

 

MS7200 Pin Moisture Meter

 

Pin type moisture meter MS7200 is used for measuring moisture content of wood,timber, paper,bamboo,carton and other relevant materials. Large display with back light Measuring range:0~95% Operation condition Temperature:-10ºC~60ºC; Humidity:5~90% Resolution:0.1; Accuracy:±0.5%n Materials Codes:3 kinds

 

MS7100 Timber Moisture Meter

 

It applicable of woodwork,paper making, flakeboard, furniture,timber traders and otherrelevant industry. It can testing 150 species woods. Large display with back light Measuring range:0~80% Operation condition Temperature:-10ºC~60ºC; Humidity:5~90% Resolution:0.1; Accuracy:±0.5%n Wood Cods:7 kinds

 

MS7100C Cotton Lint Moisture Meter

 

The Cotton Moisture Meter is avaluable testing instrument during the cotton collection,processing. It can testing cotton,spools,cotton lint and cotton bale. Large display with back light Measuring range:4~40% Operation condition Temperature:-10ºC~60ºC;Humidi ty:5~90% Resolution:0.1; Accuracy:±0.5%n

 

MS320 Tobacco Moisture Meter

 

The Tobacco Moisture Meter is a valuable testing instrument during the Tobacco collection,processing and when buying or selling. Large display with back light Measuring range:8~40% Resolution:0.1 Accuracy:±0.5%n Pin: 150mm(default); 15mm,80mm(optional)

 

MS310 Inductive Moisture Meter 

 

Used for measuring moisture content of wood, paper, bamboo,car ton, concrete,glasses textile, leather, soil and other materials. Large display with back light Measuring range:0~90% Operation condition Temperature:10ºC~60ºC; Humidity:5~90% Resolution:0.1; Accuracy:±0.5%n Material codes:20 kinds 

 

bottom of page